|
Cook Medical Inc
nester embolization coils Nester Embolization Coils, supplied by Cook Medical Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/coil+embolization+nester%C2%AE+embolization+coil/10__1097_slash_mpg__0000000000003028-21-18-21?v=Cook+Medical+Inc Average 86 stars, based on 1 article reviews
nester embolization coils - by Bioz Stars,
2026-08
86/100 stars
|
Buy from Supplier |
|
Cordis corporation
coils trufill Coils Trufill, supplied by Cordis corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/coil+embolization+nester%C2%AE+embolization+coil/pmc05322488-53-6-14?v=Cordis+corporation Average 90 stars, based on 1 article reviews
coils trufill - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Cook Medical Inc
coils Coils, supplied by Cook Medical Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/coil+embolization+nester%C2%AE+embolization+coil/pmc12950304-39-12-16?v=Cook+Medical+Inc Average 86 stars, based on 1 article reviews
coils - by Bioz Stars,
2026-08
86/100 stars
|
Buy from Supplier |
|
Cook Medical Inc
pushable coils Pushable Coils, supplied by Cook Medical Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/coil+embolization+nester%C2%AE+embolization+coil/pmc13062374-58-7-17?v=Cook+Medical+Inc Average 86 stars, based on 1 article reviews
pushable coils - by Bioz Stars,
2026-08
86/100 stars
|
Buy from Supplier |
|
Cook Medical Inc
coil size Coil Size, supplied by Cook Medical Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/coil+embolization+nester%C2%AE+embolization+coil/pmc13064461-53-2-7?v=Cook+Medical+Inc Average 86 stars, based on 1 article reviews
coil size - by Bioz Stars,
2026-08
86/100 stars
|
Buy from Supplier |
|
MicroVention terumo
lvis stent Lvis Stent, supplied by MicroVention terumo, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/coil+embolization+nester%C2%AE+embolization+coil/pmc08562288-82-32-2?v=MicroVention+terumo Average 90 stars, based on 1 article reviews
lvis stent - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Surgical Associates Ltd
coil embolization Coil Embolization, supplied by Surgical Associates Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/coil+embolization+nester%C2%AE+embolization+coil/pm19059144-16-17-1?v=Surgical+Associates+Ltd Average 90 stars, based on 1 article reviews
coil embolization - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
NeuroInterventions Inc
coil embolization ![]() Coil Embolization, supplied by NeuroInterventions Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/coil+embolization+nester%C2%AE+embolization+coil/pmc09187555-107-13-6?v=NeuroInterventions+Inc Average 90 stars, based on 1 article reviews
coil embolization - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Boston Scientific Corporation
coil embolization ![]() Coil Embolization, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/coil+embolization+nester%C2%AE+embolization+coil/pmc12363459-23-0-6?v=Boston+Scientific+Corporation Average 86 stars, based on 1 article reviews
coil embolization - by Bioz Stars,
2026-08
86/100 stars
|
Buy from Supplier |
|
NuMED Inc
12 ×20mmtyshak ii balloon ![]() 12 ×20mmtyshak Ii Balloon, supplied by NuMED Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/coil+embolization+nester%C2%AE+embolization+coil/pm37070477-36-2-12?v=NuMED+Inc Average 90 stars, based on 1 article reviews
12 ×20mmtyshak ii balloon - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
PIOLAX Inc
0.014-inch pushable coils c-stopper ![]() 0.014 Inch Pushable Coils C Stopper, supplied by PIOLAX Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/coil+embolization+nester%C2%AE+embolization+coil/pmc09440552-45-1-18?v=PIOLAX+Inc Average 90 stars, based on 1 article reviews
0.014-inch pushable coils c-stopper - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Georg Thieme Verlag KG
video 1 ![]() Video 1, supplied by Georg Thieme Verlag KG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/coil+embolization+nester%C2%AE+embolization+coil/pm30537784-50-93-79?v=Georg+Thieme+Verlag+KG Average 90 stars, based on 1 article reviews
video 1 - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Clinical Neuroradiology
Article Title: When Two Is Better than One
doi: 10.1007/s00062-021-01053-x
Figure Lengend Snippet: Female patient with an incidental right supraophthalmic internal carotid artery aneurysm. a Planning 3D-rotational angiogram demonstrated the wide-necked aneurysm on the posterior ICA wall with an acute angle between the aneurysm neck and the parent artery creating a ledge. b A Synchro 0.014in. microwire ( white dashed arrow ) was navigated across the aneurysm; however, due to the off-set between the 0.027in. microcatheter and the microwire the tip of the microcatheter ( black arrow ) was stuck on the ledge ( white arrow ) between the aneurysm neck and the parent artery preventing to be advanced distally. c , d An X‑pedion 0.010in. (Medtronic, Minneapolis, MN, USA) microwire ( black dashed arrow ) was then introduced into the Phenom 0.027in. parallel to the Synchro 0.014in. and provided the necessary support for the microcatheter to be advanced past the aneurysm and positioned distally. e , f A 4.75 × 18 mm Pipeline Flex embolization device (Medtronic, Minneapolis, MN, USA) was subsequently deployed. The cone beam CT demonstrated a good wall apposition
Article Snippet: This technique has been reported in
Techniques:
Journal: Clinical Neuroradiology
Article Title: When Two Is Better than One
doi: 10.1007/s00062-021-01053-x
Figure Lengend Snippet: Female patient with a family history of aneurysmal subarachnoid hemorrhage and incidental left paraophthalmic internal carotid artery. a 3D angiogram demonstrates the wide-necked aneurysm just distal to the origin of the ophthalmic artery. b Attempts to navigate a Marksman microcatheter over a Synchro 0.014in. microwire positioned in the left M2 were unsuccessful with the catheter tip being caught on the ophthalmic artery origin ( white arrow ). Note, a second microcatheter with a wire ( black arrow ) is being advanced into the aneurysm which was later used for coiling. c Adding an X‑pedion 0.010in microwire ( black dashed arrow ) within the Marksman microcatheter, which was advanced similarly into the left M2, provided the necessary support for the microcatheter to traverse across the ophthalmic segment for distal positioning. d – f A 4.75 × 18 mm Pipeline Flex embolization device was subsequently deployed and the aneurysm was coiled
Article Snippet: This technique has been reported in
Techniques:
Journal: Journal of Vascular Surgery Cases, Innovations and Techniques
Article Title: Percutaneous transthoracic coil embolization of a gutter-related type Ia endoleak after chimney thoracic endovascular aortic repair
doi: 10.1016/j.jvscit.2025.101906
Figure Lengend Snippet: (A) Digital subtraction angiography after transthoracic access to the false lumen showing a type Ia endoleak and (B) subsequent resolution of the type Ia endoleak after coil embolization of the gutter.
Article Snippet:
Techniques:
Journal: Journal of Vascular Surgery Cases, Innovations and Techniques
Article Title: Percutaneous transthoracic coil embolization of a gutter-related type Ia endoleak after chimney thoracic endovascular aortic repair
doi: 10.1016/j.jvscit.2025.101906
Figure Lengend Snippet: (A) Retraction of the sheath over a microcatheter while injecting contrast to delineate the outer edge of the aorta, identified by a change in the pattern of contrast dispersion, and (B) subsequent glue embolization through the microcatheter, beginning within the false lumen and extending to just beyond the outer edge of the aortic wall.
Article Snippet:
Techniques: Dispersion
Journal: Journal of Vascular Surgery Cases, Innovations and Techniques
Article Title: Percutaneous transthoracic coil embolization of a gutter-related type Ia endoleak after chimney thoracic endovascular aortic repair
doi: 10.1016/j.jvscit.2025.101906
Figure Lengend Snippet: (A) Computed tomography angiography (CTA) 2 months after percutaneous transthoracic retrograde coil embolization of a gutter endoleak demonstrating complete resolution of the endoleak and (B) the presence of Histoacryl glue at the level of the puncture site.
Article Snippet:
Techniques: Computed Tomography
Journal: Journal of Medical Case Reports
Article Title: Transcatheter arterial embolization for hemothorax caused by spinal fracture without arterial injury: a case report and review of the literature
doi: 10.1186/s13256-022-03568-4
Figure Lengend Snippet: Angiography of the right tenth intercostal artery. A Selective angiography revealed no arterial injury, and no spinal branches were depicted. B Pooling of contrast medium (arrows) within the vertebral body was observed in the late phase. C Post-embolization angiography showing arterial occlusion and no contrast medium staining and pooling in the vertebra. D Digital angiography image taken after embolization of the bilateral tenth intercostal arteries
Article Snippet: After
Techniques: Staining
Journal: Journal of Medical Case Reports
Article Title: Transcatheter arterial embolization for hemothorax caused by spinal fracture without arterial injury: a case report and review of the literature
doi: 10.1186/s13256-022-03568-4
Figure Lengend Snippet: Management algorithm for hemothorax caused by spinal fracture. CECT contrast-enhanced computed tomography, TAE transcatheter arterial embolization
Article Snippet: After
Techniques: Computed Tomography